Microscope Name | Upright or Inverted? | Objective Lenses | Fluorescence Colours | Techniques |
---|---|---|---|---|
Axioplan | Upright for slides | Magnification up to 100x oilSuitable for coverslips | Blue, Green, Red, Far-Red | Zeiss Axioplan 2 microscope with QImaging QClick camera for high sensitivity and high resolution fluorescence microscopy and differential interference contrast (DIC) of fixed specimens on slides |
Axio Imager | Upright for slides | Magnification up to 100x oilSuitable for coverslips | Blue, Green, Red, Far-Red (Cyan and Yellow available on request) | Zeiss Axio Imager A1 microscope with QImaging Retiga EXi for high sensitivity and high resolution fluorescence microscopy and phase contrast of fixed specimens on slides |
Axioskop 3 | Upright for slides | Magnification up to 100x oilSuitable for coverslips | Blue, Green, Red | Zeiss Axioskop microscope with QImaging QICAM colour camera for moderate to high resolution fluorescence microscopy and imaging of histologically or histochemically stained specimens on slides. Motorised stage supports tiling and stitching of specimens. |
Inverted for TC dishes | Long distance air lenses up to 40xSuitable for TC plasticware | Blue, Green, Red | Leica DMIRB microscope with Hamamatsu Orca NRB camera. Good for moderate resolution fluorescence microscopy and phase contrast of fixed/live specimens on slides, or in dishes and plates with glass or plastic bottoms | |
Leica 2 | Inverted for TC dishes | Long distance air lenses up to 40xSuitable for TC plasticware | Blue, Green, Red | Leica DMIRB microscope with Leica DFC7000T colour camera for high resolution fluorescence microscopy and colour imaging of histologically or histochemically stained specimens on slides, or in dishes and plates with glass or plastic bottoms |
...
Microscope Name | Upright or Inverted? | Objective Lenses | Laser Lines | Techniques |
---|---|---|---|---|
Radiance | Upright for slides | Air, oil Suitable for coverslips and water dipping lenses up to 60x | 458, 488, 514, 543, 635 | Bio-Rad Microscience Radiance 2100 with Nikon 800 stand and three high-sensitivity GaAsP detectors for 3D imaging of fixed specimens on slides. DIC. Live imaging of specimens in gasket sealed chambers or open dishes possible using a heated stage adapter and lens heater. Fluorescence recovery after photobleaching (FRAP). |
SPE | Upright for slides | Up to 63x oil (Suitable for coverslips and water dipping lenses available) | 405, 488, 532, 640 | Leica TCS SPE with DM2500 stand for 3D imaging of fixed specimens on slides. Live imaging of specimens in dishes possible with water dipping lenses using Oko-lab stage adapter or Warner Instruments perfusion chamber. DIC (not dipping lenses). Spectral imaging.SPE |
SPE2 | Upright for slides | Up to 63x oil (water dipping lenses available)Suitable for coverslips | 405, 488, 532, 640 | Leica TCS SPE with DM2500 stand for 3D imaging of fixed specimens on slides. Live imaging of specimens in dishes possible with water dipping lenses using Oko-lab stage adapter or Warner Instruments perfusion chamber. DIC (not dipping lenses). Spectral imaging. |
SPE3 | Inverted10x air to 63x oil | Suitable for coverslips | 405, 488, 561, 640 | Leica TCS SPE version 2 with DMI4000 stand for 3D imaging of specimens on slides and in dishes. DIC. Spectral Imaging. Motorised stage for multi-position acquisition and tiling. Matrix Screener software for high content screening. |
SP5 | Inverted10x air to 63x oil (63x glycerol available) | Suitable for coverslips | 405, 457, 476, 488, 495, 561, 594, 633 | Leica TCS SP5 with DMI6000B for 3D imaging of specimens on slides and live imaging of specimens in 35 mm dishes and Lab-Tek chambered coverslips using Pe-Con incubation equipment. Spectral imaging. DIC. Motorised stage for multi-position acquisition and tiling. FRAP wizard. Förster Resonance Energy Transfer with FRET wizard. Experiment design using Live Data Mode. Matrix Screener for high content screening. |
Olympus FV1200 | Inverted | 10x to 60x oilSuitable for coverslips. Silicon oil lenses for live imaging | 405, 458, 488, 515, 559, 635 | Olympus FV1200 with IX83 microscope stand. Live imaging using Tokai-Hit stage adapter for dishes and chambered coverslips. Two spectral detectors, one PMT and two GaAsP detectors for high sensitivity imaging. DIC. Motorised stage. 32x and 60x silicon lenses for thick living specimens. Additional SIM scanner with 405 pulsed laser for ablation experiments and 440 nm laser for excitation of CFP. FRAP possible with or without SIM scanner. |
Spinning Disc Confocal Microscopes
...