Microscope Name

Upright or Inverted?

Laser Lines

Key FeaturesLive Imaging

Techniques

Vox

Inverted

405, 488, 561, 640

Perkin Elmer Ultraview Vox with Yokogawa CSU-X1 DSU and Nikon TiE stand. Hamamatsu C9100-13 EMCCD camera. Photokinesis Unit for FRAP. Motorised stage. Piezo focus.

Imaging of live specimens in 35 mm dishes, Lab-Tek chambered coverslips and Ibidi uSlides using Solent Scientific cage type incubation chamber.

Sensitive and gentle high-speed live confocal imaging. This machine has a smaller field of view than the 3i but the image acquisition speed is higher. DIC. Multi-point and stitching. Good for FRAP. CLEM.

3iInverted405, 440, 488, 514, 561, 640

Yokogawa CSU-W1 spinning disc and Zeiss Axio Observer Z1 stand. Photometrics Prime 95b and Andor iXon 888 Life EMCCD cameras. Vector for FRAP. Motorised stage. High speed piezo focus

Oko-Lab cage incubator with CO2 chamber and adaptors for 35 mm dishes, chambered coverslips and multi-well plates.Sensitive and gentle high-speed live confocal imaging. This machine has a larger field of view than the Vox but the image acquisition speed is not quite as high. Multi-point and stitching. FRAP.

Time-lapse inverted microscope systems

Microscope

Objective Lenses
Upright or Inverted?

Fluorescence Colours

Camera

Key Features

Live Imaging

Techniques

GFP1

10x to 40x air and LWD (oil lenses available)

Green and Red

Greyscale high sensitivity CCD
Inverted

Green, Red, Far-Red

Zeiss Axio Observer Z1 stand with Hamamatsu Orca Flash4.0 v2 sCMOS camera. Motorised stage. Fluorescence. Phase Contrast.

Solent Scientific chamber with adaptor for multi-well plate. Other adaptors available on request.

Optimally configured for 'screening' of multiple positions in multi-well plates and other vessels at low to moderate resolution and high sensitivity using phase contrast and fluorescence.

Stage adapters support Nunc and Mat-Tek multi-well plates and 35 mm Mat-Tek dishes. If you need to use another vessel or adapter you must contact Andrew Vaughan

GFP2

10x to 40x air and LWD (oil lenses available)

Blue, Green and

GFP2

Inverted

Cyan, Green, Red and Far-Red

Greyscale high sensitivity CCD


Optimally configured for 'screening' of multiple positions in multi-well plates and other vessels at low to moderate resolution and high sensitivity using phase contrast and fluorescence. Stage adapters support Nunc and Mat-Tek multi-well plates and 35 mm Mat-Tek dishes. If you need to use another vessel or adapter you must contact Andrew Vaughan

N-STORM (coming soon)

10x air to 100x oil TIRF lens

GFP3

Inverted

Blue, Green

,

and Red

and Far-Red

. Cyan and Yellow available on request.

Greyscale ultra-high sensitivity EMCCD


Optimally configured for high resolution and high sensitivity fluorescence microscopy of living specimens in XYZT for deconvolution, TIRF and super-resolution using N-STORM and dSTORM.