h1. Axio Imager
{float:right}!Axio

...

-Imager.jpg|border=1!{float}

*Location: MRC Building, First Floor, Room 1.19.

...

*

AxioImager is a Zeiss AxioImager upright microscope ideal for viewing  slide-mounted samples using phase contrast or fluorescence microscopy.  It has a QImaging QIClick camera designed for taking greyscale images of  fluorescent samples with high sensitivity to low light levels. All  microscope controls are manual apart from camera image capture, which is  through Improvision's Openlab software.

...



To report problems or request help please email [lmcbimage@lmcb.mcbl.ucl.ac.uk

...

Objective lenses on Axio Imager

Magnification

Immersion

Designation

NA

Contrast

Coverslip Correction (mm)

10X

Air

EC Plan Neofluar

0.3

Ph1

0.17

20X

Air

EC Plan Neofluar

0.5

Ph2

0.17

40X

Oil

EC Plan Neofluar

1.3

Ph3

0.17

63X

Oil

Plan Apochromat

1.4

Ph3

0.17

100X

Oil

EC Plan Neofluar

1.3

Ph3

0.17

Fluorescence filter sets on Axio Imager

Filter Turret

Turret Position

Dyes

Excitation Filter

Dichroic Mirror

Emission Filter

1

DAPI

350/50

400LP

460/50

2

DIC

N/A

N/A

Analyser

3

Empty

N/A

N/A

N/A

4

GFP

470/40

495LP

525/50

5

Texas Red

560/40

585LP

630/75

6

Cy5

620/60

660LP

665LP

...

|mailto:lmcbimage@lmcb.mcbl.ucl.ac.uk].

h3. Objective lenses on Axio Imager

|| Magnification || Immersion || Designation || NA || Contrast || Coverslip Correction (mm) ||
| 10X | Air | EC Plan Neofluar | 0.3 | Ph1 | 0.17 |
| 20X | Air | EC Plan Neofluar | 0.5 | Ph2 | 0.17 |
| 40X | Oil | EC Plan Neofluar | 1.3 | Ph3 | 0.17 |
| 63X | Oil | Plan Apochromat | 1.4 | Ph3 | 0.17 |
| 100X | Oil | EC Plan Neofluar | 1.3 | Ph3 | 0.17 |

h3. Fluorescence filter sets on Axio Imager

|| Filter Turret || Turret Position || Dyes || Excitation Filter || Dichroic Mirror || Emission Filter ||
| 1 | DAPI | 350/50 | 400LP | 460/50 |
| 2 | DIC | N/A | N/A | Analyser |
| 3 | Empty | N/A | N/A | N/A |
| 4 | GFP | 470/40 | 495LP | 525/50 |
| 5 | Texas Red | 560/40 | 585LP | 630/75 |
| 6 | Cy5 | 620/60 | 660LP | 665LP |

h3. Links

* [Using Volocity on the Axio Imager|^Using_Volocity_on_Axio_Imager.pdf]
* [Using Openlab to take images|^Acquisition-using-Openlab.pdf]
* [Openlab User Guide|http://cellularimaging.perkinelmer.com/pdfs/manuals/OpenlabUserGuide.pdf]
* [Volocity User Guide|http://cellularimaging.perkinelmer.com/pdfs/manuals/VolocityUserGuide.pdf]
* [Axio Imager controls|^AxioImagerControls.pdf]