Use a widefield microscope if your specimen is thin and relatively free of out-of focus blur or you don't need to optically section it for processing, analysis and visualisation in 3D.

Microscope Name

Microscope Model

Upright or Inverted?

Objective Lenses

Fluorescence Colours

Camera

Automation

Techniques

Axioplan

Zeiss Axioplan 2

Upright

10x air to 100x oil

Blue, Green, Red, Far-Red

Greyscale high sensitivity CCD

Manual

Good for high sensitivity and high resolution fluorescence microscopy and differential interference contrast (DIC) of fixed specimens on slides

Axio Imager

Zeiss Axio Imager A1

Upright

10x air to 100x oil

Blue, Green, Red, Far-Red (Cyan and Yellow available on request)

Greyscale high sensitivity CCD

Manual

Good for high sensitivity and high resolution fluorescence microscopy and phase contrast of fixed specimens on slides

Axioskop 3

Zeiss Axioskop

Upright

10x air to 100x oil

Blue, Green, Red

Colour CCD

Motorised

Good for moderate to high resolution fluorescence microscopy and colour imaging of histologically or histochemically stained specimens on slides. Supports tiling and stitching.

Leica

Leica DMIRB

Inverted

10x air to 40x LWD*

Blue, Green, Red

Greyscale high sensitivity CCD

Manual

Good for moderate resolution fluorescence microscopy and phase contrast of fixed/live specimens on slides or in dishes and plates with glass or plastic bottoms

Leica 2

Leica DMIRB

Inverted

10x air to 40x LWD*

Blue, Green, Red

Colour CCD

Manual

Good for moderate resolution fluorescence microscopy and colour imaging of histologically or histochemically stained specimens on slides or in dishes and plates with glass or plastic bottoms

*Long Working Distance

Confocal

Use a confocal if your specimen in thick, has significant out-of-focus blur, or if you need to process, analyse or visualise it in 3D.

Microscope Name

Microscope Model

Upright or Inverted?

Objective Lenses

Lasers

Detectors

Simultaneous/Sequential

Manual/Automated Stage

Climate Control

Techniques

Radiance

Bio-Rad Microscience Radiance 2100 with Nikon E800 stand

Upright

10x air to 60x oil (water dipping lenses available)

Argon, 543, 635

3x GaAsP

Simultaneous and Sequential

Manual

Available (heat only)

Imaging of specimens on slides and in gasket sealed chambers or open dishes using dipping lenses. DIC. FRAP.

SPE

Leica TCS SPE with DM2500 stand

Upright

10x air to 63x oil (water dipping lenses available)

405, 488, 532, 640

1x PMT

Sequential only

Manual

Available

Imaging of specimens on slides and live specimens in Warner Instruments perfusion chamber using dipping lenses. DIC. Spectral imaging.

SPE

Leica TCS SPE with DM2500 stand

Upright

10x air to 63x oil (water dipping lenses available)

405, 488, 532, 640

1x PMT

Sequential only

Manual

Available

Imaging of specimens on slides and live specimens in open dishes using Oko-Lab incubation equipment and dipping lenses. DIC. Spectral imaging.

SPE3

Leica TCS SPE version 2 with DMI4000 stand

Inverted

10x air to 63x oil

405, 488, 561, 640

1x PMT

Sequential only

Automated

No

Imaging of specimens on slides and in dishes. DIC. Spectral Imaging. Multi-point and stitching. Matrix Screener.

SP5

Leica TCS SP5 with DMI

Inverted

10x air to 63x oil (63x glycerol available)

405, Argon, 561, 594, 633

1x PMT and 3x Hybrids

Simultaneous and Sequential

Automated

Available

Imaging of specimens on slides and in 35 mm dishes and Lab-Tek chambered coverslips using Pe-Con incubation equipment. Spectral imaging. DIC. Multi-point and stitching. FRAP. FRET. Live Data Mode. Matrix Screener.

Vox


Inverted

10x air to 100x oil (60x water immersion available)

405, 488, 561, 640

1x EMCCD camera

Sequential only

Automated

Available

Imaging of live specimens in 35 mm dishes, Lab-Tek chambered coverslips and Ibidi uSlides using Solent Scientific cage type incubation chamber. DIC. Multi-point and stitching. FRAP.

Time-lapse inverted microscope systems

Microscope

Objective Lenses

Fluorescence Colours

Camera

Techniques

GFP1

10x to 40x air and LWD (oil lenses available)

Green and Red

Greyscale high sensitivity CCD

Optimally configured for 'screening' of multiple positions in multi-well plates and other vessels at low to moderate resolution and high sensitivity using phase contrast and fluorescence. Stage adapters support Nunc and Mat-Tek multi-well plates and 35 mm Mat-Tek dishes. If you need to use another vessel or adapter you must contact Andrew Vaughan

GFP2

10x to 40x air and LWD (oil lenses available)

Blue, Green and Red

Greyscale high sensitivity CCD

Optimally configured for 'screening' of multiple positions in multi-well plates and other vessels at low to moderate resolution and high sensitivity using phase contrast and fluorescence. Stage adapters support Nunc and Mat-Tek multi-well plates and 35 mm Mat-Tek dishes. If you need to use another vessel or adapter you must contact Andrew Vaughan

N-STORM (coming soon)

10x air to 100x oil TIRF lens

Blue, Green, Red and Far-Red

Greyscale ultra-high sensitivity EMCCD

Optimally configured for high resolution and high sensitivity fluorescence microscopy of living specimens in XYZT for deconvolution, TIRF and super-resolution using N-STORM and dSTORM.