MICROSCOPE: Axio Observer.Z1 SR, inverted, motorized


 

PALM/STORM RESOLUTION 

XY

~ 20 - 30 nm

Z

~ 50 - 80 nm

3D STORM axial range with double phase ramp

~ 1400 nm

SIM RESOLUTION 

XY

~ 100 - 120 nm 

Z

~ 200 - 300 nm

SIM axial range

up to 20 µm into tissue

IMAGING MODES

Photoactivation Localization Microscopy (PALM)

Strucured Illumination Microscopy (SIM)

Widefield (WF) (sample illumination with arc lamp)

Laser Widefield (laser sample illumination in EPI, HiLo or TIRF mode) 

LIGHT SOURCES  

Light source

Wavelengths [nm]

Nominal power [mW]

HR Diode

405

50

HR Diode

488

200

HR DPSS

561

200

HR Diode

642

160

X-Cite Lumen Dynamics (XLED)

UVX 375 - 400, BDX 450 - 495, GYX 540 - 600   

N/A

OBJECTIVE LENSES

Objective

Magnification

Immersion Medium

Numerical Aperture

Coverslip correction [mm]

Working Distance [mm]

EC Plan-Neofluar

10x

air

0.3

0.17

5.2

LCI Plan-Neofluar Imm Korr DIC M27 

25x

water

0.8

adjustable, 0 - 0.17

0.21 at cover glass 0.17

EC Plan-Neofluar OIL DIC M27

40x

oil

1.3

0.17

0.21

C-Apochromat Korr M27

63x

water

1.2

adjustable, 0.14 - 0.19

0.28 at cover glass 0.17

Plan-Apochromat DIC M27

63x

oil

1.4

0.17

0.19

alpha Plan-Apochromat DIC M27 Elyra

100x

oil

1.46

0.17

0.11

FLUORESCENCE FILTER SETS

Two 6-position emission filter turrets are available for imaging on the Zeiss ELYRA PS.1, one with single-bandpass filters and another one with multi-bandpass filters.   

Single-band emission filter set 

Turret position

Emission filter

Excitation filter

Example Fluorophores

1

Transmission light

N/A

N/A

2

Triple-band filter (labelled None)

N/A

most common fluorophores in the visible range

3

BP 420 - 480/LP 750

MBS 405

DAPI

4

BP 495 - 550/LP 750

MBS -488

GFP, Alexa Fluor 488

5

BP 470 - 620/LP 750

MBS -561

mCherry, Texas Red

6

LP 655

MBS -642

Cy5, Alexa Fluor 647

Multi-band emission filter set   

Turret position

Emission filter

Excitation filter

Example Fluorophores

1

Empty

N/A

N/A

2

Empty

N/A

N/A

3

BP 420 - 480/BP 570 - 640/LP 740

MBS 405/561

DAPI & mCherry

4

BP 420 - 480/BP 495 - 550/LP 650

MBS 405/488/642

DAPI, GFP & Cy5

5

LBF -561/642

MBS -561/642

Alexa Fluor 555 & Alexa Fluor 647

6

LBF -488/561

MBS 405ac/488/561

DAPI, GFP & mCherry

CAMERA/DETECTOR   

Camera

Pixels

Pixel Size [µm]

Quantum Efficiency (QE)

Andor iXon 897 (EMCCD) for PALM imaging (left side port)

512 x 512

16 x 16

90%

pco.egde sCMOS for SIM imaging (base port)

1280 x 1280

6.5 x 6.5

57%, dynamic range 15 bit

INCUBATION

The microscope is fully enclosed in a blacked out chamber and equipped with a TokaiHit unit (INU series, Model: ELY)

SOFTWARE

ZEN Black Version 11.0.2.190

ADDITIONAL INFORMATION

Z drive DC servomotor (smallest Z step size 25 nm)

motorized XY piezo scanning stage motorized (range 130 mm x 100 mm, max. sped 100 mm/s, step resolution 0.2 µm)  

Z-piezo stage insert for XY scanning stage (max. travel range 100 µm, min. 5 nm step size)  

stage inserts available for standard slides, glass-bottom dishes and LabTek chambers

definite focus

EPI, HILO and TIRF illumination mode

image reconstruction algorithms for SIM and PALM data

 

 

 

 

 